Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Med (Lausanne) ; 9: 936816, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35847817

RESUMO

Rationale: Abnormal values of hypercoagulability biomarkers, such as D-dimer, have been described in Coronavirus Disease 2019 (COVID-19), which has also been associated with disease severity and in-hospital mortality. COVID-19 patients with pneumonia are at greater risk of pulmonary embolism (PE). However, the real incidence of PE is not yet clear, since studies have been limited in size, mostly retrospective, and PE diagnostic procedures were only performed when PE was clinically suspected. Objectives: (1) To determine the incidence, clinical, radiological, and biological characteristics, and clinical outcomes of PE among patients hospitalized for COVID-19 pneumonia with D-dimer > 1,000 ng/mL. (2) To develop a prognostic model to predict PE in these patients. Methods: Single-center prospective cohort study. Consecutive confirmed cases of COVID-19 pneumonia with D-dimer > 1,000 ng/mL underwent computed tomography pulmonary angiography (CTPA). Demographic and laboratory data, comorbidities, CTPA scores, treatments administered, and clinical outcomes were analyzed and compared between patients with and without PE. A risk score was constructed from all these variables. Results: Between 6 April 2020 and 2 February 2021, 179 consecutive patients were included. The overall incidence of PE was 39.7% (71 patients) (CI 95%, 32-47%). In patients with PE, emboli were located mainly in segmental/subsegmental arteries (67%). Patients with PE did not differ from the non-PE group in sex, age, or risk factors for thromboembolic disease. Higher urea, D-Dimer, D-dimer-to-ferritin and D-dimer-to-lactate dehydrogenase (LDH) ratios, platelet distribution width (PDW), and neutrophil-to-lymphocyte ratio (NLR) values were found in patients with PE when compared to patients with non-PE. Besides, lymphocyte counts turned out to be lower in patients with PE. A score for PE prediction was constructed with excellent overall performance [area under the ROC curve-receiver operating characteristic (AUC-ROC) 0.81 (95% CI: 0.73-0.89)]. The PATCOM score stands for Pulmonary Artery Thrombosis in COVID-19 Mallorca and includes platelet count, PDW, urea concentration, and D-dimer-to-ferritin ratio. Conclusion: COVID-19 patients with pneumonia and D-dimer values > 1,000 ng/mL were presented with a very high incidence of PE, regardless of clinical suspicion. Significant differences in urea, D-dimer, PDW, NLR, and lymphocyte count were found between patients with PE and non-PE. The PATCOM score is presented in this study as a promising PE prediction rule, although validation in further studies is required.

2.
Diagnosis (Berl) ; 2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34090321

RESUMO

OBJECTIVES: Quality control of ultrasonography markers is necessary to ensure greater efficacy of prenatal aneuploidy screening. The aim of this study was to assess the quality of the crown-rump length (CRL) and nuchal translucence (NT) measurement accuracy by the laboratory according to quality indicators. METHODS: Retrospective observational study on 4,908 single-foetus pregnant women who underwent prenatal aneuploidy screening in the first trimester of pregnancy. Euploid foetuses with CRL between 45 and 84 mm were included, while those with NT≥3.5 mm were excluded. CRL measurement was considered to be accurate if the median multiples of the median (MoM) for pregnancy-associated plasma protein A (PAPP-A) was between 0.90 and 1.10. Fifteen sonographers participated in the study, six of whom comprised the control group. Systematic error for a sonographer was considered when CRL measurement was greater than ±2 mm with respect to the control group. Quality for NT was assured by means of the WHIRI method and each sonographer cumulative sum control chart (CUSUM). RESULTS: For CRL accuracy, five sonographers underestimated the measurements, while another four overestimated them, with no statistical differences. For smaller sized foetuses, all sonographers met the established specifications. Regarding NT control, three sonographers did not meet the quality criteria for the median MoM. All sonographers met the specifications for the logarithmic standard deviation of the NT MoM levels. Thirteen sonographers met the CUSUM specifications. CONCLUSIONS: Evaluation of a quality control of ultrasonography parameters by laboratory professionals is necessary to avoid under- or overestimation tendencies for CRL and NT measurements. CUSUM is a useful tool for the immediate correction of errors in NT measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...